QUICK 4.0 – VVVF

Control panels for machine room (for modernisation)

Microprocessor control panel with V.V.V.F. suitable for the modernization of all systems with
manual/automatic/semiautomatic doors, up to 4,5 Kw – 12 stops. Easily confi gurable to adapt to the real characteristics of the lift.
– Parallel, serial or mixed (parallel / serial) connection.
– In stock ready for delivery.
– Monitoring via Managerlift and RemoteControlAPP.

Code: QUICK 4.0-mP-FRD-5.5-PA
MANOEUVRE: VVVF-Universal / Down Collective / Full Collective
STOPS N°: Universal up to 12 / Down Collective up to 8 / Full Collective up to 6
INVERTER MODEL: Mitsubishi FRD 700 5,5 KW + keyboard + EMC filter
MAIN MOTOR: up to 4,5 KW – 380 V three phase – In 10,5A
DOORS: Manual / Semiautomatic / Automatic
TYPE OF OPERATOR: with opening-closing limit switch / Powered during travel
PARKING: Open doors / Closed doors
ACCESSES:
– N° 1 (with Semiautomatic / Automatic doors)
– N° 2 (with Manual doors)
CAR FLOOR: Fixed / Movable
SIGNALINGS: Position-Here-Engaged-Gong-Overload-Car alarm-Incoming-Reserved-Direction
SHAFT SIGNALS: Magnetic sensors with Ferrite plates
OPERATING VOLTAGE: 48 Vdc
BRAKE VOLTAGE: 48 Vdc – 60 Vdc – 70 Vdc – 80 Vdc – 95 Vdc – 110 Vdc
RETIRING CAM VOLTAGE: 48 Vdc – 60 Vdc – 70 Vdc – 80 Vdc – 95 Vdc – 110 Vdc
DOORS OPERATOR VOLTAGE: 55V three ph. – 60V three ph. – 96V three ph. – 110V three ph. – 125V three ph. – 230V three ph. – 400V three ph. – 230 Vac (VVVF)
LIGHT SIGNALINGS VOLTAGE: 12 Vdc – 24 Vdc
DOORS SLOWING DOWN VOLTAGE: 48 Vdc – 60 Vdc – 80 Vdc

Code: QUICK 4.0-mP-FRD-5.5-PA-LIM

MANOEUVRE: VVVF-Universal / Down Collective / Full Collective
STOPS N°: Universal up to 12 / Down Collective up to 8 / Full Collective up to 6
INVERTER MODEL: Mitsubishi FRD 700 5,5 KW + keyboard + EMC filter
MAIN MOTOR: up to 4,5 KW – 380 V three phase – In 10,5A
DOORS: Manual / Semiautomatic / Automatic
TYPE OF OPERATOR: with opening-closing limit switch / Powered during travel
PARKING: Open doors / Closed doors
ACCESSES:
– N° 1 (with Semiautomatic / Automatic doors)
– N° 2 (with Manual doors)
CAR FLOOR: Fixed / Movable
SIGNALINGS: Position-Here-Engaged-Gong-Overload-Car alarm-Incoming-Reserved-Direction
SHAFT SIGNALS: Magnetic sensors with Ferrite plates
OPERATING VOLTAGE: 48 Vdc
BRAKE VOLTAGE: 48 Vdc – 60 Vdc – 70 Vdc – 80 Vdc – 95 Vdc – 110 Vdc
RETIRING CAM VOLTAGE: 48 Vdc – 60 Vdc – 70 Vdc – 80 Vdc – 95 Vdc – 110 Vdc

DOORS OPERATOR VOLTAGE: 230 Vac (VVVF)
LIGHT SIGNALINGS VOLTAGE: 12 Vdc – 24 Vdc